				| MECHANICAL SPECIFICATIONS | |
|---|---|
| Materials | Housing: Aluminium Flange: Aluminium Shaft: Stainless steel | 
| Bearings | Ballraces | 
| Blind hollow shaft diameter | 10 or 12 mm | 
| Maximum number of revolutions permitted mechanically | ≤ 12000 rpm | 
| Protection according to DIN EN 60529 | IP65 | 
| Rotor inertia moment | ≤ 30 gcm² | 
| Starting torque at 20°C (68°F) | ≤ 0,03 Nm | 
| Weight aprox. | 480 g | 
| Operating temperature range | -40°C to +85°C | 
| Storage temperature range | -40° to +85° C | 
| Humidity | 98% RH, no condensation | 
| Vibration according to DIN EN 60068-2-6 | 100 m/s² (10Hz…1000Hz) | 
| Shock according to DIN EN 60068-2-27 | 1000 m/s² (6ms) | 
| Radial connection | 3 x Cable Gland (Terminal Box) 3 x M12 Connector Mating connectors not included | 
| ELECTRICAL SPECIFICATIONS | |
|---|---|
| Interface | Profibus | 
| Output Driver | Profibus Data Interface, galvanically isolated via opto-couplers | 
| Power supply | 10…30 VDC | 
| Consumption | ≤ 115 mA (10 VDC) ≤ 50 mA (30 VDC) | 
| Power Consumption | ≤ 1.5 W | 
| Start-Up Time | < 1 s | 
| Singleturn resolution | up to 16 bit | 
| Multiturn resolution | up to 14 bit | 
| Accuracy (INL) | ±0.0220° (14 – 16 bit) ±0.0439° (≤13 bit) | 
| Code | Binary | 
| Short circuit protection | Yes | 
| Protection polarity inversion | Yes | 
| EMC: Emitted Interference | DIN EN 61000-6-4 | 
| EMC: Noise Immunity | DIN EN 61000-6-2 | 
| MTTF | 13,5 years |