| MECHANICAL SPECIFICATIONS | |
|---|---|
| Materials | Housing: Aluminium Flange: Aluminium Shaft: Stainless steel |
| Bearings | Ballraces |
| Blind hollow shaft diameter | 10 or 12 mm |
| Maximum number of revolutions permitted mechanically | ≤ 12000 rpm |
| Protection according to DIN EN 60529 | IP65 |
| Rotor inertia moment | ≤ 30 gcm² |
| Starting torque at 20°C (68°F) | ≤ 0,03 Nm |
| Weight aprox. | 475 g |
| Operating temperature range | -40°C to +85°C |
| Storage temperature range | -40° to +85° C |
| Humidity | 98% RH, no condensation |
| Vibration according to DIN EN 60068-2-6 | 100 m/s² (10Hz…1000Hz) |
| Shock according to DIN EN 60068-2-27 | 1000 m/s² (6ms) |
| Radial connection | 3 x Cable Gland (Terminal box) 2 x M12 Connector Mating connectors not included |
| ELECTRICAL SPECIFICATIONS | |
|---|---|
| Interface | DeviceNet |
| Output Driver | Transceiver (ISO 11898), Galvanically Isolated by Opto-Couplers |
| Power supply | 10…30 VDC |
| Consumption | ≤ 230 mA (10 VDC) ≤ 100 mA (24 VDC) |
| Power Consumption | ≤ 2.5 W |
| Start-Up Time | < 250 ms |
| Singleturn resolution | up to 16 bit |
| Accuracy (INL) | ±0.0220° (14 – 16 bit) ±0.0439° (≤13 bit) |
| Code | Binary |
| Short circuit protection | Yes |
| Protection polarity inversion | Yes |
| EMC: Emitt ed Interference | DIN EN 61000-6-4 |
| EMC: Noise Immunity | DIN EN 61000-6-2 |
| MTTF | 13,5 years |