				| SENSOR SPECIFICATIONS | |
|---|---|
| Absolute resolution | 10 μm | 
| Accuracy | ±15 μm | 
| Repeatability | ±1 increment | 
| Signal period | 2 mm | 
| GAP, distance sensor/band (d).See previous table) | 0,3 to 1 mm | 
| Measuring lenght | up to 30 m | 
| Max. traversing speed | 300 m/min | 
| Protection class (EN 60529) | IP67 | 
| Operating temperature range | 0°C to +50°C | 
| Storage temperature range | -20°C to 70°C | 
| Humidity | 100% not condensed | 
| Vibration (EN 60068-2-6) | 200 m/s2 (55…2000 Hz) | 
| Weight | 80 g | 
| Axial connection | 2 meter cable (other cable lenght or radial output available, upon request) | 
| BAND SPECIFICATIONS | |
|---|---|
| Pole pitch | Incremental track 2+2 mm + absolute track | 
| Accuracy at 20°C | ±20 μm/m (high accuracy) | 
| Width band | 10 mm | 
| Thickness band | 1,3 mm | 
| Maximum length | 30 m | 
| Thermal expansion | 10,5 x 10¯⁶ °C¯¹ T ref = 20°C ± 0,1°C | 
| Operating temperature range | -20°C to +70°C | 
| Storage temperature range | -20°C to +80°C | 
IMPORTANT: In order not to compromise the accuracy of the system, the magnetic band must be longer than the machine run of at least 2 cm from front side and 8 cm for back side.