INCLINOMETER IN360A

ANALOG INCLINOMETER

  • Robust metal case protects from shocks and vibrations
  • Filling resin protects against thermal shocks, moisture and harsh environments
  • 1D and 2D inclination measurement
  • Protection class IP67
  • Analog output (4-20 mA or 0.5-4.5V)
  • Protected against reverse bias

 

Buy Online
Ask an expert

Our team of experts will asnwer your technical, product or application questions as soon as possible.

Name*

E-mail*

Phone

Company

Country

Message


I have read and I accept the terms and conditions.*

HOHNER AUTOMATICOS, S.L. informs you that the personal data that you provide by filling out this form will be treated with the purpose of sending you the information requested. The legitimation of the treatment is carried out through the consent of the interested party. Failure to enter your personal data will make it impossible to meet your request. You can exercise your rights of access, rectification, cancellation and deletion of personal data by contacting info@encoderhohner.com or by post to HOHNER AUTOMATICOS, S.L., Prolongació C/Sant Francesc, s/n, 17400 - Breda (Girona) Spain.

Fields with a * are required.

Download Datasheet

Plaease enter your email to download product Datasheet.

E-mail

I have read and I accept the terms and conditions.*

HOHNER AUTOMATICOS, S.L. informs you that the personal data that you provide by filling in this form will be treated with the purpose of sending you the information requested. You can exercise your rights of access, rectification, cancellation and deletion of personal data by contacting info@encoderhohner.com.

If you need 3D step-file of your reference contact us and you will receive it within one working day.

Do you have questions or need an offer?

Contact us

  • 5 + 61 =
MECHANICAL SPECIFICATIONS
Materials Housing: Anodized aluminium
Protection according to DIN EN 60529 IP67
Weight 200 g
Operating temperature range -40° .. +85° C
Storage temperature range -40° .. +85° C
Connection 0,5 m open lead cable
ELECTRICAL SPECIFICATIONS
Measurement range 0…360° (1 axis)
±30° (2 axes)
Resolution 7.33 μA (4…20 mA)
1.67 mV (0,5…4,5 V)
Supply voltage 12/24 V (7…30 V)
Current consumption* 40 mA
Accuracy ±0.20° (max ±0.50°)
Temperature drift ±0.008 deg/°C
Load resistor 250 Ω; max 500 Ω (4…20 mA)
10 kΩ (0,5…4,5 V)

(*) Sensor current consumption is 40mA. At X and Y full scale (20mA+20mA), the total current consumption is 80mA.

Categories: , ,
Reference example: IN360A-114, IN360A-115, IN360A-214, IN360A-215